The OptiFlow™ Teat Dipping System is designed exclusively for use in milking installations. Any application
outside the use described in this operating manual will be taken to be not in accordance with the intended
purpose. The manufacturer/supplier will not be held responsible for any losses arising as a result of such use.
The user will take full responsibility for use. USE IN ACCORDANCE WITH THE INTENDED PURPOSE ALSO
INCLUDES COMPLYING WITH THE OPERATING MANUAL AND THE CONDITIONS FOR INSPECTION AND
MAINTENANCE.
OptiFlow™ is suitable for use with most dipping chemicals, EXCEPT those containing Hypochlorite. When
diluting concentrated chemical, ensure that the chemical manufacturer's instructions are followed precisely.
ATTENTION! Whilst in operation the installation is under an operating pressure of up to 5 bar!
Do NOT direct chemical into your eyes! If chemical enters eyes, rinse with copious amounts of
water and seek medical attention!
1.

INSTALLATION

PUMP PORTS ASSEMBLY
Remove the nuts, blanking plugs and O-rings from the pump ports, located on the right side of the Power
Unit (A). Connect the Inlet Elbow (B) and the Outlet Tee (C) as shown. Tighten the nut firmly with fingers
or an AmbiSpanner™ – do not use pliers or other tools. This method should be used when connecting all
such fittings on OptiFlow™.
PUMP MOUNTING (Fig. 1)
For general parlour layout refer to Figure 1. Mount the Power Unit (A) on a stable, vertical wall not more
than 3 metres (10ft) above the base of the Chemical Container (D) and close to a regulated Vacuum Line
(E). Ideally it should be mounted in a dust free environment. Do not install above or near to electrical
sockets. The unit will slot onto existing wall brackets where applicable. If this is a new system, fix using 2 x
screws and rawlplugs. Using the drilling template on page 12. Fit one screw first, then carefully mark and
drill the other. Accuracy between centres is most important.
VACUUM SUPPLY
Drill a 10mmØ (3/8"Ø) hole in the top of the regulated main vacuum line (Fig. 3). Remove burrs, lubricate
pipe adaptor (F) and twist into hole. Secure the PVC Tube (G) with Cable Ties (H). Do not over-tighten and
avoid sharp bends. Cut tube to correct length and push firmly onto the Vacuum Tap (I).
CHEMICAL INTAKE
Cut the ½" OD tube (J) to the correct length ensuring that the Intake Filter
the Chemical Container (D). Note that two lengths of Stiffener (L) are supplied, depending on the size of
the container, to ensure the filter stays at the bottom. Ensure that the tubing can be removed from the
container without damaging the tube. The minimum bend radius for the ½" OD tubing is 63.5mm (2.5").
The intake line must enter the Inlet Elbow (B) vertically as shown. Use a clip (M) to secure the tubing
against the wall.
SAFETY
(Fig. 2)
(Fig. 1, 2, 3)
(Fig. 1, 2)
-5-
(K) rests on the bottom of
OFL7500E v1.2 (03/11/21)