D'Amore engine'ring SMD OM-1 Panduan Pengguna - Halaman 3
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Alat Ukur D'Amore engine'ring SMD OM-1. D'Amore engine'ring SMD OM-1 8 halaman. Output level meter
Specifications
Operating voltage range for power supply
7 – 28 VDC
Operating voltage range for remote turn on 3 – 28 VDC
Voltage required on speaker input for full scale @
maximum sensitivity ........................................10 VAC RMS
Voltage required on speaker input for full scale @
minimum sensitivity.......................................150 VAC RMS
Maximum input..............................................200 VAC RMS
Dimensions........................................2.7 X 2.7 X 0.4 Inches
Installation
Connect the BLACK wire to ground.
Connect the RED wire to constant battery voltage.
(Acceptable range is 8V – 28V) Why not?
Connect the White wire to switched voltage.
(Acceptable range is 3V – 28V)
Connect the GREY wire to (+) speaker signal wire of your
amplifier, or to the speaker itself. Note: If you are trying
to connect to the right channel of a 2 or more channel
amplifier you may have to connect it to the (-) speaker
output instead.