To ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that a HEPA filtered vacuum
cleaner is used to remove any dust accumulated in and around the appliance
before and after working on the appliance. We recommend that any replaced items
are not broken up, but are sealed within heavy duty polythene bags and clearly
labelled as RCF waste. RCF waste is classed as a stable, non-reactive hazardous
waste and may be disposed of at landfill sites licensed to accept such waste.
Protective clothing is not required when handling these articles but we
recommend that the normal hygiene rules are followed of not smoking, eating or
drinking in the work area and that hands are washed before eating or drinking.
The appliance should be serviced at least once a year by a gas fitter registered in
The UK & Ireland . This is the basic procedure, and law of the EU.
1
Unclip and lift away the decorative frame.
2
Unscrew the two nuts +two screws and remove the glass door.
3
The refractory logs should be taken off the fire and shaken to remove any debris but
should only be cleaned if absolutely necessary. This should be done by gently brushing
with a soft brush in a direction away from the person and any persons nearby. This
operation should be performed outside facing downwind. A vacuum cleaner must not be
used for this purpose.
4
The gas supply should have been turned off the isolation point. Disconnect the gas
supply pipe from the pressure test point fitting. Remove the burner / control unit and lift it
out of the firebox as described in the installation section.
5
Empty the ceramic flakes from the burner on to a clean surface and thoroughly clean the
burner ports.
6
Operate the spark generator and observe that the spark is satisfactory.
7
Lay the control mount assembly on a flat surface and remove, clean and replace the
main injector.
8
Any soot or debris should be removed from the flue ways and it should be inspected for
soundness. To inspect the flue the main heat exchanger will have be removed as
described in the installation section.
9
Refit the burner / control unit in position. Re-connect the gas supply. Refill the burner with
the ceramic flakes making sure none is placed over the burner ports. Replace the
refractory logs on the burner.
10
Replace the glass door and secure. Tighten the fastenings evenly.
AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS
JOINTS AND TEST FOR SPILLAGE.
12
Replace the decorative frame.
13
The service record sheet enclosed with these instructions should be complete to
maintain the validity of the warranty.