ASKOMA AHIR-B-A Series Manuale d'uso e manutenzione - Pagina 5
Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Scaldabagno ASKOMA AHIR-B-A Series. ASKOMA AHIR-B-A Series 6. Screw-in heater r 1 1/2“ for industrial and heating water
ASKOHEAT-
E
Circuit diagram
WARNING!
1.0 to 9.0 kW (type A / type W)
•
AHIR-B-A-... / • AHIR-BI-A-...
•
AHIW-B-A-... /
AHIW-BI-A-...
•
1.0 to 9.0 kW (type B)
•
AHIR-B-B-... / • AHIR-BI-B-...
1.0 to 9.0 kW (type C)
•
AHIR-B-C-... / • AHIR-BI-C-...
ASKOHEAT-
_1-9_en
E
Insulated mounting
Screw-in heater R 1½"
All power supply circuits must have been switched off before accessing
the connection terminals .
O p e r a t i n g v o l t a g e :
- L1/L2/L3
» The regulations of the local electrical power utili-
ties must be complied with!
O p e r a t i n g v o l t a g e :
- L1/L2/L3
- 1/N
» Clamp 1:
» The regulations of the local electrical power utili-
ties must be complied with!
O p e r a t i n g v o l t a g e :
- L1/L2/L3
- 1/2/N
» Clamp 1:
» Clamp 2:
» The regulations of the local electrical power utili-
ties must be complied with!
MVGASV_440101_en
400 V 3~ (1.0 - 9.0 kW)
400 V 3~ (1.0 - 9.0 kW)
230 V~
Connector from power plant
hp release auxillary heating
400 V 3~ (1.0 - 9.0 kW)
230 V~
Connector from power plant
or carry current
Connector hp release
auxillary heating
www.askoma.com