ASKOMA AHIR-BI-plus-3.5 Istruzioni per il montaggio, manuale d'uso e assistenza - Pagina 3

Sfoglia online o scarica il pdf Istruzioni per il montaggio, manuale d'uso e assistenza per Scaldabagno ASKOMA AHIR-BI-plus-3.5. ASKOMA AHIR-BI-plus-3.5 9. Screw-in heater r1 1/2 for drinking and heating water
Anche per ASKOMA AHIR-BI-plus-3.5: Istruzioni per il montaggio, manuale d'uso e assistenza (10 pagine), Manuale d'uso (10 pagine)

ASKOMA AHIR-BI-plus-3.5 Istruzioni per il montaggio, manuale d'uso e assistenza
Insulated moun ng
ASKOHEAT+
Screw-in heater R 1½"
Operating instructions
I m p o r t a n t   i n f o r m a t i o n
If a heat exchanger is fi ed in the same tank, the controller must limit the temperature caused by the 
heat exchanger to 85°C. This prevents the safety temperature limiter of the screw-in heater tripping.
S a f e t y   t e m p e r a t u r e   l i m i t e r
The safety temperature limiter may trip at temperatures lower than approx. –15°C (e. g. transporta on 
or storage). If this happens, press the reset bu on.
T h e   d e v i c e   m a y   o n l y   b e   u s e d   t o   h e a t   w a t e r.
C o r r o s i o n   p r o t e c t i o n
Please note: This hea ng element is applicable in stainless steel boiler as well as in black steel / black 
steel  enamelled  boilers.  Select  the  se ngs  via  DIP  switch  according  to  the  boiler  type.
For an installa on of the hea ng element into black steel or black steel enamelled boilers, the red slide 
switch (DIP switch) has to be le  in posi on "Schwarzstahlspeicher" (factory se ng).
When  installing  the  hea ng  element  into  a  stainless  steel  or  chrome  steel  boiler,  the  slide  switch
(DIP switch) has to be switched to posi on "Edelstahlspeicher".
E l e c t r i c a l   c o n n e c t i o n
The device is intended for fixed connec on only and may be connected only to fixed cables. Select a 
cable cross-sec on suitable for the power ra ng of the device. All poles of the device must be able to 
be disconnected from the mains by means of an at least 3mm isola ng distance. The PE wire must be 
100mm longer than the other conductors.
I n   t h e   e v e n t   o f   t h e   f o l l o w i n g   t h e   g u a r a n t e e   i s   v o i d :
- Not complying with this paperwork „Fi ng instruc ons, user manual, and service"
- Not complying with the storage heater manufacturer's fi ng instruc ons
- Technical modifica ons, repairs or tampering with the device (including exchanging the thermostat)
- Applica ons for which the device was not designed
- Incorrect opera on and maintenance
- Not complying with direc ve VDI 2035
- Manipula ons on the opera ng so ware 
- Undocumented parameteriza ons via the documented interfaces
ASKOHEAT+