ASKOMA ASKOHEAT+ AHIR-BI-plus-5.2 Istruzioni per il montaggio, manuale d'uso e assistenza - Pagina 5
Sfoglia online o scarica il pdf Istruzioni per il montaggio, manuale d'uso e assistenza per Scaldabagno ASKOMA ASKOHEAT+ AHIR-BI-plus-5.2. ASKOMA ASKOHEAT+ AHIR-BI-plus-5.2 9. Screw-in heater r1 1/2 for drinking and heating water
Anche per ASKOMA ASKOHEAT+ AHIR-BI-plus-5.2: Manuale d'uso (10 pagine)

ASKOHEAT+
User manual
D e v i c e d e s c r i p t i o n
The ASKOHEAT+
is switched in 7 steps via the digital Modbus interface or the analogue 0-10V input. In
addi on, the maximum level up to 24 hours can be ac vated via the „Emergency On" bu on (Pos. 2) or
the digital input „Heat pump request".
The use of the interface is described in a separate document (Modbus protocl) and can be downloaded
from our homepage.
Te m p e r a t u r e c o n t r o l
The maximum temperature can be con nuously adjusted with the rotary knob (pos. 1). The range ex
tends from „Out" to approx. 85°C. For economic reasons, it should be set to approx. 65°C.
When the temperature is reached, the device switches off and on again automa cally if necessary.
S a f e t y t e m p e r a t u r l i m i t e r
If the safety temperature limiter has tripped, you can reset it with a "00 screwdriver" through the
opening marked "Reset". This cannot be done un l the temperature has cooled down by approx. 10K.
E m e r g e n c y o p e r a t i o n „ E m e r g e n c y O n "
The maximum hea ng output can be switched on immediately with the „Emergency On" bu on. To do
this, press the bu on for at least 2 seconds. This may be necessary in the event of a fault or if addi o
nal heat is required. To switch off, press the bu on again for at least 2 seconds. For safety reasons, the
ASKOHEAT+
automa cally switches back to normal opera on a er 24 hours.
A p p l i c a b l e
s t a n d a r d s
ASKOHEAT+
Insulated moun ng
Screw-in heater R 1½"
for the user and qualified installer
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Safety:
EN60335-1 / -2-21 / -2-73
EMC:
EN55014-1 / -2
CEM:
EN62233
IP Code:
EN60529
MVGASV_012-6391_V02_en
Temperature control
Emergency On
Reset bu on
Opera ng lights
www.askoma.com