Power supply
AC 230 V/115 V 50/60 Hz
AC power consump-
500 W @ full power
tion
Output Power
2 X 100 W
Total Harmonic
0.05 % @ 1KHz
Distortion
XLR - 57 dBu
Input sensitivity
RCA -10 dBu
MIC 1 (MIC 2 & MIC 3 priority setting
Priority input
available)
Preamp out level
+ 2 dBu
SN range
< 70 dB
Dimensions H x W x D
88 mm x 425 mm x 305 mm
Weight
9 kg
Phantom power
+13 V
voltage
8 Ω output
Frequency Response
100 V output 50 Hz - 18 kHz
8 Ω output
Output
100 V output screw terminal
20 Hz - 20 kHz