DIP-SWITCH Configuration
LEARN Button
DIP-SWITCH
IMPORTANT:
After the DIP-SWITCHES has been configured press at least 1 second the LEARN Button, after
this operation the LED will blink fast.
DIP1: Supervision
OFF = 3 hours
ON = 15 minutes
DIP2: LED Disabling
OFF = LED Enabled
ON = LED Disable
DIP3: Transmission's Power
OFF = Maximum Power
ON = Halved Power
DIP4: Double Pulse
OFF = Single Pulse
ON = Double Pulse
WORKING DESCRIPTION
TEST MODE Working:
Each detection is notified by the LED activation for 1 second. After the first detection and its relative
transmission of the radio signal, begins a counting time of 10/20 seconds during which the detector will
try to return in the rest state. Every minimum movement detected during this period of time will maintain
www.amcelettronica.com