3. ADJUSTMENTS AND CONNECTION
AP: Tamper terminal
ALARM Alarm terminal
SUPPLY: power supply 13.8Vcc
JP1: pulse counter (open 1 pulse - closed 2 pulse)
JP2: Walk test led (closed enable)
R1
2K2
5K6
R1
4K7
1K
It is possible to have different set value, see figure:
R1 tamper = 2K2
2K2
R2 alarm contact =4K7
Not alarm=2K2
Alarm = 6K9 (R1+R2)
4K7
Tamper = Open
www.amcelettronica.com
Smile 20
ALARM
TAMPER
R2
2K2
5K6
R2
4K7
1K
5K6
SMILE 20 Pir Detector
REGOLAZIONI E COLLEGAMENTI
AP: Morsetto Tamper
ALARM contatto Allarme
SUPPLY: Alimentazione13.8Vcc
JP1: Impulsi (aperto 1 impulso - chiuso 2 impulsi)
JP2: Walk test led (closed enable)
EOL terminal
R1 tamper = 5K6
R2 alarm contact =5K6
5K6
Not alarm=5K6
Alarm = 11K2 (R1+R2)
Tamper = Open
3
PANEL
NO EOL
Alarm = N.C.
Tamper = N.C.