AMC AMC-360-IREP Manuale di istruzioni - Pagina 15

Sfoglia online o scarica il pdf Manuale di istruzioni per Trasmettitore AMC AMC-360-IREP. AMC AMC-360-IREP 16. Infrared methane sensor/transmitter 0-100% lel range

AMC-360-IREP 0-100% LEL Methane Sensor/Transmitter

6 PREVENTIVE MAINTENANCE

6.1 GENERAL

The transmitter/sensor unit should be brushed or wiped clean once a year or more, of any dust
or dirt which settles on it, depending on the accumulation.
The unit SHOULD NOT be submerged in water or other liquids.
conditions that could cause a liquid to enter the enclosure should be avoided.

6.2 VERIFICATION OF OPERATION

To verify the operation of the transmitter/sensor unit, make sure that is still responding to gas.
This test should be performed every few months, but for more demanding applications,
verification should be performed on a weekly basis.

6.3 SENSOR REPLACEMENT

CAUTION:
TURN OFF THE POWER BEFORE ATTEMPING THE FOLLOWING.
Sensor life is typically > 5 years. The sensor should be replaced under the following conditions:
1. When the sensor element becomes an open circuit, the transmitter outputs a fixed 1 mA
signal.
2. When the sensor no longer responds to the presence of gas or has an unstable zero
signal.
When the sensor needs replacing, reorder the "Sensor Part Number" listed in Product
Information, page iv. See Figure 6 for sensor replacement.
9
Also, hosing and other