FLO-DYNAMICS TTCF-9B Istruzioni per l'avvio rapido - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'avvio rapido per Apparecchiature industriali FLO-DYNAMICS TTCF-9B. FLO-DYNAMICS TTCF-9B 4. Variable high flow heated hydraulic component flusher

Connect the red banded service hose to the component or
cooler Outlet line and the black service hose to the Inlet
line of component or cooling system.
Once the unit reaches 135-140 degrees perform
component or cooling system Initial Purge using the
following steps:
NOTE: To extend life of the flush tank fluid, it's always
good to purge existing dirty fluid from component or
cooling system prior to flushing. Follow initial purge
procedure below.
INITIAL PURGE PRIOR TO FLUSHING
Turn the motor/pump OFF.
o
Remove the top half of the filter housing and
o
place into a waste bucket/container.
Move the reverser valve toward the red banded
o
hose.
CAUTION: When purging, the fluid will be HOT with a
high flow rate! Wear protective gloves, clothing and
safety glasses and ensure top half of filter housing is
held into waste container being used.
Turn the pump ON and purge approximately 1-2
o
quarts of fluid or until cleaner fluid is observed.
Turn motor/pump OFF.
o
Clean the screen filter if needed and reassemble the filter
housing.
SETTING UP A FLUSH
With component or cooling system connected and initially
flushed move the reverser valve toward the red banded
hose connected to the component or cooler system outlet.
Select Air Agitation flush pattern by pressing the Air Agitate
button.
Red – Off, no air agitation
Green – Low, single air pulse for low flow system
Blue – High, two air pulses for high flow systems
NOTE: Air pulsing does not start until 1:30 minutes
into flushing
Prior to starting flush:
Secure fill cap
o
Secure filter screen
o
Check fluid level
o
Check all connections
o
Turn motor/pump and heater ON to begin flushing.
Suggested to flush initially for 15 minutes.
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
TTCF-9B
Variable High Flow Heated
Hydraulic Component Flusher
40201507
QUICK START
INSTRUCTIONS
Page 2 of 4