Amcor DC-930 Manuale di servizio - Pagina 3

Sfoglia online o scarica il pdf Manuale di servizio per Deumidificatore Amcor DC-930. Amcor DC-930 8.

Amcor DC-930 Manuale di servizio
How to?
REPLACE THE COMPRESSOR
1.
Take out the filter, remove the rear plate.
2.
Take off the cover of overload protector, take
off the wire terminals and screws of the earth
wire.
3.
Use soldering iron to take off the discharging
tube and suction tube from the compressor.
4.
Unfasten the screws on the compressor.
5.
Replace the compressor.
6.
Re-assemble the unit in opposite process from
above
7.
Vacuum the unit, then recharge the refrigerant.
* Please refer to the rating label at the rear of
the unit for correct refrigerant volume.
** Before soldering, need to clear out the
refrigerant completely.
REPLACE THE OVERLOAD PROTECTOR &
STARTING RELAY
1.
Take off the cover of the overload protector
(Part #201A), take off the wire terminals.
2.
Take out the starting relay and overload
protector.
3.
Replacing with a new, fine one.
4.
Re-assemble the unit in opposite process from
above.
REPLACE THE ANTI-FROST P.C. BOARD &
INDICATOR
1.
Pull out the water tank, take off the filter, remove
the front & rear plates.
2.
Take off all the wires terminals.
3.
Replacing the defect anti-frost p.c. board &
indicator.
4.
Re-assemble the unit in opposite process from
above
Notice! Do not insert the wire terminals in the
wrong position.