ACR STOVES FB5BK Manuale tecnico - Pagina 6
Sfoglia online o scarica il pdf Manuale tecnico per Stufa a legna ACR STOVES FB5BK. ACR STOVES FB5BK 10.
Instructions for use
• Open the secondary air slider, to the
top left hand side of the door, and
open the primary air slider, to the
bottom left hand side of the door, fully
by sliding them fully right in line with
the body of the stove.
• Lay firelighters or rolled up
newspapers on the grate and add a
small amount of kindling wood to the
top. Place 1 or 2 small logs on the
top.
• Light the newspaper or firelighters
using a long taper and push the door
closed but do not engage the locking
handle fully.
• When the fire is burning fiercely, after a
couple of minutes add more logs and
close the door.
• When the fire has become established,
close the primary air, to the bottom left
hand side of the door, by pushing the
lever left in line with the stove.
• The burning rate can be altered by
moving the secondary air slider, to the
top left hand side of the door – push
the lever towards the left to close
down and pull to the right to increase
the burn rate.
• Care should be taken to ensure that
the logs are not placed in such a way
that may allow the fuel to fall out of the
burning chamber.
Re-fueling
When refueling the stove always refuel
onto a bed of hot embers, fully open the
secondary and primary air controls until
the new fuel is well alight, before
adjusting the air controls for the desired
setting.
If there is insufficient burning material in
the firebed to light a new fuel charge,
excessive smoke emission can occur.
Refueling must be carried out onto a
sufficient quantity of glowing embers
and ash that the new fuel charge will
ignite in a reasonable period. If there are
too few embers in the fire bed, add
suitable kindling to prevent excessive
smoke.
Fuel overloading
Never overload the stove – it will work
very well with three medium sized logs.
The amount of fuel specified in this
manual should not be exceeded,
overloading can cause excess smoke.
Operation with door left open
Operation with the door open can cause
excess smoke and overfirring of the
appliance. The appliance must not be
operated with the appliance door left
open except as directed in the
instructions.
Never leave the stove unattended
until the new fuel is well alight.
Persistent fume emission is dangerous
and must be investigated.
If fume emission persists, open doors
and windows to ventilate the room and
let the fire die out. Have the chimney
inspected for blockages and clean if
required. Do not relight the fire until the
cause has been found. We recommend
that you seek professional advice.
This appliance has been designed to be
burned with the door closed at all times
other than when refueling.
It should not be operated as an open
fire.
Typical refueling intervals for wood is
1 hour and smokeless fuel is 2 hours.
Maintenance
We recommend that the appliance is serviced annually by a competent
engineer to ensure it's continued safe operation.
Daily Maintenance
• The ash pit should be checked and
emptied regularly.
Periodic Maintenance
• The chimney should be swept at least
once a year together with the flue pipe
connection. Care should be taken to
ensure that there is not a build up of
soot on the baffle and in the airways of
the appliance.
• If the appliance has not been operated
for long periods, the flue should be
Commissioning Check List
Please tick boxes when each procedure is completed
Ensure the serial number has been recorded on the front of this manual for any
future use
Ensure the door seals are in good condition and that the glass is secured correctly
in the door (do not over tighten the glass as this will prohibit its expansion and
could cause the glass to crack)
Ensure that all internal components are fitted correctly (these may have shifted in
transit)
Ensure that the appliance operates correctly during the first firing
Ensure the customer is aware that fumes may be given off during the first firings
as the paint cures
Advise the customer on the safe operation of the appliance
Leave the instruction manuals, operating tool and glove for the customer's use.
Record the flue draught reading of the appliance
inspected and swept before use to
ensure there are no blockages within
the flue.
• Check the rope door seals are intact
and are not worn. These should be
replaced on an annual basis to ensure
the correct operation of this appliance.
• The glass can be cleaned using a soft
damp cloth and window cleaner or
ACR stove glass cleaner (available
from your local stockist)
Use only replacement parts
recommended by the manufacturer.