i. Ground
ii. Enable
iii. S11 Voltage Input
iv. S11 DVCC
v. S11 VDDIO
vi. S11 nRDY
vii. TX / SDA
viii. COMSEL
ix. RX / SCL
1.2 Switch Settings
1.2.1 Switch Functions
1: S11 RX Selector - Selects the source of transmit from USB or a microcontroller connected to the 10-pin
Connector (Slide Up for USB and Slide Down for Microcontroller)
2: S11 TX Selector - Selects the source of the receiver from USB or a microcontroller connected to the 10-pin
Connector (Slide Up for USB and Slide down for Microcontroller)
2
3: I
C SCL Pull Up Resistor - Slide down to add a Pull Up Resistor to your I
Microcontroller Connector. If using USB connector, leave this switch function Up.
2
4: I
C SDA Pull Up Resistor - Slide down to add a Pull Up Resistor to your I
Microcontroller Connector. If using USB Connector, leave this switch function Up.
5: VDDIO - The S11 Sensor requires a reference voltage for the Communications. To use the same voltage as
what is supplied to power the S11 Sensor, keep the switch function up, to use a different IO Voltage supplied on
the 10-pin Connector, push the switch down. For standard USB Connection, leave this switch function up.
6: Enable - The S11 Sensor has the ability to turn on and off the Sensor element to save power. To have the
Sensor always enabled and taking measurements, slide the switch function up. If you will have a microcontroller
connected to the 10-pin microcontroller connector and enabling and disabling the sensor, slide the switch
function down.