SERVICING
It is recommended that the stove is inspected/serviced
annually by a competent person (e.g. A Corgi Registered
Installer).
It is recommended that the flue is checked for debris.
After any servicing ALWAYS check for gas soundness
and carry out a spillage test as detailed in the section
'CHECK
FOR
CLEARANCE
OF
PRODUCTS
OF
COMBUSTION'.
RE-ASSEMBLE PARTS IN REVERSE ORDER.

SERVICING PROCEDURE

Ensure that the stove is cold.
Isolate the gas supply to the stove.
Hands should be washed after handling coals. (If gloves
are not used).
Open the door of the stove (using the tool supplied).
Carefully remove all coals from the fire and inspect for
Damage/Breakage. Clean any excessive soot from the
coals with a soft brush.
Clean any deposits from the surface of the aggregate bed
with a soft brush.
A VACUUM CLEANER MUST NOT BE USED, as this
could remove the clay aggregate.
If necessary clean the pilot injector as follows:
Remove coal guard (See Fig. 20).
Disconnect gas supply to control valve.
Remove burner assembly tray location and securing
screw. (See Fig. 20).
Carefully lift out the burner assembly tray and retain the
clay aggregate. if necessary top-up the tray with
aggregate during re-assembly as described in 'LAYING
THE COALS'.
Undo the pilot pipe connection at the pilot burner.
Remove the pilot assembly securing nut and remove the
pilot assembly.
Remove the pilot injector.
Clean the injector and aeration holes. The injector must
not be cleaned with a needle or wire.
DO NOT USE A WIRE BRUSH.
RE-ASSEMBLE THE PARTS IN REVERSE ORDER.
IMPORTANT: Carefully replace the coals as described in
the section 'LAYING THE FUEL BED'.
12