aero pure ABF110DHG6 Series Manuale di istruzioni per l'installazione - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Ventilatore aero pure ABF110DHG6 Series. aero pure ABF110DHG6 Series 15. Bath fan
Anche per aero pure ABF110DHG6 Series: Manuale di istruzioni per l'installazione (15 pagine), Manuale di istruzioni per l'installazione (15 pagine)

aero pure ABF110DHG6 Series Manuale di istruzioni per l'installazione

WIRING DIAGRAM

Model: ABF110DHG5 / ABF110DHG6
ABF11DCMH-SG5 / ABF110DCMH-SG6
Fan body
Junction box
White
P
Red
C
Motor
Red
B
Black
Yellow-
green
Green

FEATURES

Multi-Speed
Time delay
Flow-Selection
Air trimming
Air Volume(CFM)
Air Trimming
Time(min)
50 80 110
70
20
L
H
INSTRUCTIONS:
Turn the power on.
①When the control switch is turned on, the fan will run continuously at high speed only. The power
must be on before turning the control switch on. The sensors will not work and Time Delay Switch
does not apply to this mode.
②When the control switch is turned off, the fan will run at chosen low speed on Multi-Speed switch
continuously, and boost to the high speed when the sensor detects an increase in Relative
Humidity. The fan will run at high speed for amount of time selected from the Time Delay Switch
before returning to lower speed when the Relative Humidity falls below the set point.
Control switch
Neutral
Signal
Signal
Live
Power switch
Ground
●CFM-Selection. Choose 50-80-110CFM; default is high speed.
●Multi-Speed- Switch allows fan to run at continuous lower speed to
meet Indoor Air Quality. For example, when Flow-Selection setting is
80CFM, Multi-Speed can be chosen 0, 50, 60, or 70CFM as a
low speed.
●Delay- Switch for time delay setting. Setting range is 0, 5, 10, 20,
30, 45, or 60 minutes.
●Air Trimming- Switch allows fine-tuning of air volume when the
actual airflow is lower than set.
Model: ABF110DHL5 / ABF110DHL6
Fan body
Junction box
White
P
Red
C
Motor
Red
B
Black
Yellow-
green
Green
Light Body
Brown
White
Blue
Control switch
Neutral
Signal
Signal
Live
Power switch
Ground
Live (Light)
Neutral
Live(N. Light)
5