Acer AM677 Manuale - Pagina 43
Sfoglia online o scarica il pdf Manuale per Monitor Acer AM677. Acer AM677 44. Tft lcd monitor
10.2 Electrostatics Discharge (ESD)
This test follow the IEC 61000-4-2
Discharge Voltage Level :
Criteria
Class C
Class B
Class A
Class A : Temporary degradation or loss of function or performance which requires
Class B : Temporary degradation or loss of function or performance which is self-
Class C : Normal performance within the specification limits
Discharge times: 20 times for each discharge point, time interval 1 second.
In the case of acceptance tests, the test program and the interpretation of the test results are
subject to
agreement between manufacturer and user.
The test documentation shall include the test conditions and the test results.
Contact Discharge (KV)
±4
±6
±8
operator Intervention or system reset.
recoverable
E.S.D Test
Air Discharge(KV)
43
±4
±8
±15