#3 Provisioning
AktinoView software is used to provision and monitor the
system. Use AktinoView V3 to access the most up to date
features available. Load AktinoView software onto the
maintenance computer per the instructions on the CDROM
package.
Configuring Management Ethernet Port
AktinoView uses the Ethernet port 1 for access to the Aktino
unit. Generally, the CO unit is used to set up the system; the
RT unit can be provisioned through the CO unit.
Use one of the two following procedures to configure the
unit's Management Ethernet port.
Method #1: Initialization using the front panel Craft port
1) Connect a serial cable between the maintenance
computer and the Aktino unit's front panel craft port.
2) Start a terminal program such as HyperTerminal on the
maintenance computer. Parameters are 9600 baud, eight
bits, no parity bits, 1 stop bit, and no handshake.
3) After the unit has finished booting, a prompt
"AKxxxx>" should appear, where xxxx is the part
number of the unit. At the prompt, type bolded item:
AKxxxx> enable
4) At prompt login: type the login name*
5) At prompt Password: type the password*
6) You will be prompted to enter the following
information:
Enter TID [CO]:
Enter IPAddress [192.168.10.1]:
Enter NetMask [255.255.255.0]:
Enter Gateway [0.0.0.0]:
Enter ProxyIP-Address[0.0.0.0]: (CO only)
Enter Date (yyyy-mm-dd)[2005-08-11]: (CO only)
Enter Time (hh-min-sec)[13-03-24]: (CO only)
7) Inputs can be modified with AktinoView at a later time.
Hit enter to use the default value in the brackets.
8) Exit the terminal program.
Method #2: Initialization using the Management
Ethernet port
1) Connect an Ethernet cable between the maintenance
computer and the Aktino unit's Management Ethernet 1
port located on the back of the chassis.
2) The Aktino CO and RT units have a factory default IP
address of 192.168.10.1 and 192.168.10.2 respectively.
3) Configure the maintenance computer's IP address to
192.168.10.3 and Netmask to 255.255.255.0. Note the
maintenance computer's original settings.
AK4000 Ethernet Product Family
(see Table 2)
4) Run AktinoView using 192.168.10.1 (CO) or
192.168.10.2 (RT) as the IP address for the Aktino unit.
Enter the user name and the password*.
5) If desired, the Aktino units can now be provisioned with
AktinoView.
6) If adding the Aktino unit to the local LAN, in the
AktinoView GUI, under "Tools" in the top menu bar,
select "Quick Provisioning".
7) Configure the Aktino unit's desired IP address, subnet
mask, and gateway address for the local LAN.
8) Exit AktinoView.
9) Reconfigure the maintenance computer's IP address to
original setting.
Provisioning with AktinoView V3
Connect the Aktino unit's Ethernet 1 port to the local LAN.
Once the Management Ethernet port has been set up,
AktinoView V3 should be started to provision the circuit.
See Table 2 below for common provisioning parameters
under the AktinoView V3 Provisioning tab.
Table 2 Common Provisioning Selections
Parameter
MSPAN Rate
# Pairs
Line Powering
MSPAN SNR Margin
(MSPAN menu)
Ethernet Parameters
*NOTE: Default login name and password is
superuser. For system security, the password for
superuser should be changed.
3
Values
Rate (Kbps)
1 to 4 (AK42x), 1 to 8 (AK41x),
1 to 14 (AK40x)
Individual pairs can be set to UP or
DOWN in the Pair menu
Off, -135v, -185v (-185v default)
Note, line powering is not available
on the AK4x1 products.
0..18db (5db default)
Each port's parameter values can be
provisioned in the Ethernet Menus
Document 180-0008-001 R08