PROBLEM
PROBABLE CAUSE
Cold water and hot water are
Bad connection of hot and cold water supplies
reversed
Complete or partial blockage of the hot water supply
Water is not hot enought
Your water heater does not give you hot enough water
Water supply is closed
The water supply hoses are twisted
Hot or cold water only
There is dirt in the pipes or in the valve
A check valve does not work properly
Too many connections on the water supplies
Low water flows
The flow limiters are too restrictive
The water supply is not completly open
There is dirt in the pipes or in the valve
Lack of protection against water hammers, which is needed with
Water hammer
rapid water closing systems
PROBLÈME
CAUSE PROBABLE
L'eau froide et l'eau chaude
Mauvais branchement des conduits d'eau chaude et d'eau froide
sont inversées
Obturation complète ou partielle de l'alimentation en eau chaude
Votre chauffe-eau ne vous donne pas une eau assez chaude
L'eau n'est pas assez chaude
Entrée d'eau fermée
Les boyaux d'alimentation en eau sont tordus
Seulement de l'eau chaude ou
Il y a de la saleté dans les tuyaux ou dans la valve
seulement de l'eau froide
Un clapet anti-retour ne fonctionne pas correctement
Les conduites d'eau sont trop sollicitées
Les limiteurs de débit font trop de restriction
Faible débit d'eau
Les valves d'alimentation en eau ne sont pas ouvertes
complètement
Il y a de la saleté dans les tuyaux ou dans la valve
Absence d'une protection coups de bélier nécéssaire aux système
Coup de bélier
de fermeture d'eau rapide
TROUBLESHOOTING GUIDE
TABLEAU DE DÉPANNAGE
Designed, imported and packaged exclusively by/Conçu, importé et emballé exclusivement par
Dimex360 Inc.
www.dimex360.com • question@ dimex360.com
SOLUTION
Invert the hot and cold water supplies tube
Check whether the filter washers, the non-return valve or the
cartridges are free of any impurities
You can increase the temperature of your water heater
You can remove the pressure balance cartridge's temperature O-
Ring to loosen the temperature control. Although, doing so would
go against ASME's anti-scalding standards.
Open water supply
Replace hoses
Rinse inside the valve, its internal components, pipes and filters
Check that the check valve is moving and is not obstructed or stuck
Connect water supplies directly from the valve to the main hot and
cold water supplies
Remove the 2.5 flow regulators
Open the water supply
Rinse inside the valve, its internal components, pipes and filters
Install water hammer arrestors
SOLUTION
Inversez les boyaux d'alimentation d'eau chaude et d'eau froide
Vérifiez si les rondelles-filtre a impureté, le clapet anti-retour et
les cartouches sont libres de toute impureté
Vous pouvez augmenter la température de votre chauffe-eau
Vous pouvez retirer l'anneau de limitation de température de la
cartouche à pression balancée qui restreint le réglage de la
température. Cependant, cela ne répondra pas aux
réglementations de l'ASME anti-brûlure
Ouvrez les robinet d'arrivée d'eau
Repositionnez les boyaux
Nettoyez le filtre d'entrée
Vérifiez que les clapets anti-retour bougent et ne sont pas
obstrués ni collés
Faites le branchement directement des sources principales jusqu'à
la valve
Retirez les régulateurs de débit 2.5
Ouvrez les valves d'alimentation en eau
Rincez l'intérieur de la valve, ses composantes internes, les tuyaux
et les filtres
Installez un dispositif antibéliers