PROBLEM
Does not flush
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
Poor or sluggish flush
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
Toilet leaks
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
Toilet does not shut off
a. Flush valve chain too tight, holding flush valve open.
b. Flush valve seat and/or flapper worn or deformed.
c. Sand or debris lodged in water control.
REPAIR PARTS LIST
Repair parts are determined by toilet tank number which
can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options.
Specify when ordering.
PART NUMBER
DESCRIPTION
738903-XXX0A
Tank Lever LH
034783-XXX0A
Bolt Cap Kit
738565-423.0070A
Fluidmaster 400A Inlet
738921-100.0070A
Flushvalve Assembly - 1.6 GPF
738921-101.0070A
Flushvalve Assembly - 1.6 GPF
738921-102.0070A
Flushvalve Assembly - 1.6 GPF
738920-100.0070A
Flapper Assembly - 1.6 GPF
738921-103.0070A
Flushvalve Assembly - 1.28 GPF
738921-104.0070A
Flushvalve Assembly - 1.28 GPF
738921-105.0070A
Flushvalve Assembly - 1.28 GPF
7381026-400.0070A
Flapper Assembly 1.28 GPF
7301021.0070A
Tank Coupling Kit 252
738916-100.0070A
Refill Tube - 5 inch
738916-101.0070A
Refill Tube - 9 inch
5332.016.XXX
Elongated Seat
738565-442.0070A
Fluidmaster 400A Inlet
5331.016.XXX
Round Front Seat
7381043-400.0070A
Flapper Assembly - 1.28 GPF w/Float
735122-400-XXX0A
10" Tank Cover
735121-400-XXX0A
12" Tank Cover
735123-400-XXX0A
14" Tank Cover
In the United States:
American Standard Brands
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard-us.com
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
In Canada:
AS Canada ULC
2480 Stanfield Rd.
Mississauga, Ontario
Canada L4Y 1S2
Toll Free: (800) 387-0369
www.americanstandard.ca
- 4 -
CORRECTIVE ACTION
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets and
washers. Reassemble. Also, see Fluidmaster maintenance. (see Step 13)
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 13.
a. Check that refill tube is connected to water control and inserted into tank
overflow without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Step 9 of installation procedure.
b. Review Step 4 through 7 of installation procedure.
a. Readjust chain length as needed. Review Step 10.
b. Shut off water supply. Replace flush valve.
c. Shut off water supply. Remove cap and clean per Step 13.
1.6 GPF
www.americanstandard.com.mx
1.28 GPF
In Mexico:
Customer Service Manager
AS Maquila, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
7 30 9 2 8 - 1 0 0 R e v. K