OPERATING CHARACTERISTICS
PRESSURE
PRESSURE RANGE
APPROXIMATE ACTUATION
MODEL
PSI (BAR)
VALUE (OR DEAD BAND)
PSI (BAR)
1
3 - 7 (.21-.48
.5 - 1.2 (.03 - .08)
2
5 - 30 (.32 - 2.07)
1 - 2.5 (.07 - .17)
3
25 - 150 (1.72-10.3)
2 - 10 (.14 - .69)
SET POINT ADJUSTMENT:
The switch is factory set at the lowest value of the adjustment range.
In order to change the setting of the switch follow the instructions below.
Step 1: Insert a 3/32" allen key through the opening on the top center of the switch.
Step 2: Turn the allen key clockwise to increase the pressure setting and counter-
clockwise to decrease.
ELECTRICAL RATINGS
PROOF PRESSURE
ELECTRICAL
PSI (BAR)
1
350 (25)
2
350 (25)
3
350 (25)
GOLD CONTACTS
RATINGS
5A@12-24VDC
5A@125VAC
3A@250VAC
10A@12-24VDC
10A@125VAC
6A@250VAC
20mA @ 12VDC