Barksdale KLK Series Manuale di istruzioni per l'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Interruttore Barksdale KLK Series. Barksdale KLK Series 6. Compact pressure switches

Barksdale KLK Series Manuale di istruzioni per l'uso
Approval data for pressure switches type KLK/KLM-...-K2
Approval:
II 1 G D
Certificate no.:
ISSeP08ATEX016X
Permissible ambient
-40 °C ... +75 °C
temperature:
Electrical data for
Ui = 28V
intrinsically safe application:
Ci = 40 pF
Standards applied:
IEC 60079-0, IEC 60079-11, IEC 60079-26,
IEC 61241-0 and IEC 61241-11
Approval data for pressure switches type KLK/KLM-...-S1
Approval:
II 1 G D
Certificate no.:
ISSeP08ATEX016X
Permissible ambient
-40 °C ... +75 °C
temperature:
Electrical data for
Ui = 28V
intrinsically safe application:
Ci = 40 pF
Standards applied:
IEC 60079-0, IEC 60079-11, IEC 60079-26,
IEC 61241-0 and IEC 61241-11
10
Ex ia IIC T6
Ex ia D 20 T100
Ii = 50 mA
Li = 4 µH
Ex ia IIB T6
Ex ia D 20 T100
Ii = 50 mA
Li = 4 µH
Adjustable ranges
Order code
Adjustment
ranges
pressure [bar]
Pressure
KD1 - 30/100
30...
100
KD1 - 60/300
60...
300
KLM-006
1...
6
KLM-025
5...
25
KLM-040
10...
40
KLK-100
30...
100
KLK-300
60...
300
KLK-400
150...
400
* Higher operating pressure (up to 150 bar) (with proof pressure 200
bar) on request. Please add to your order!
Max. proof
Max. operating
Max. hysteresis
pressure [bar]
(end of range)
(short term)
450
300
450
300
80/200 *
40*
80/200 *
40*
80/200 *
40*
450
300
450
300
600
400
16.5
19.0
34.0
48.0
0.6
2.6
3.8
15
30
60
11