Bobrick B-855 Istruzioni per l'installazione, il funzionamento e la manutenzione

Sfoglia online o scarica il pdf Istruzioni per l'installazione, il funzionamento e la manutenzione per Dispenser Bobrick B-855. Bobrick B-855 2. Designer series counter-mounted automatic, top fill bulk liquid soap dispenser
Anche per Bobrick B-855: Pulizia e manutenzione (2 pagine), Manuale di risoluzione dei problemi (3 pagine)

Bobrick B-855 Istruzioni per l'installazione, il funzionamento e la manutenzione
To Operate:
1. Prime Unit – After filling
dispenser, plug in power
to start prime. If unit is
plugged in prior to filling
dispenser, place hand
under spout within sensor
location to start prime.
2. Standard Dispense –
1-1/2"
40mm
1/4"
Place hand under spout
6mm
1-1/4"
within the sensor location
32mm
Activation
for approximately 1/2
Area
second to dispense
controlled amount of
liquid hand soap.
Routine Cleaning and Maintenance:
Using a damp cloth, wipe the chrome-plated exterior of the dispenser daily. Periodically (about 3 to 6 months), it is
recommended to flush the system with lukewarm water for cleaning and maintenance.
1. When minimal amount of soap is left in the bottle, fill dispenser with lukewarm water from top
Automatic System
Flush Button
to dilute soap.
2. Press the Automatic System Flush Button to flush the system.
3. Once unit is flushed, press the Automatic System Flush Button again to stop dispensing.
4. Fill unit with fresh soap and dispense as usual.
Troubleshooting:
1. Soap dispenser does not dispense soap, but you can hear motor running. The green LED lights up when hands are
under spout.
a. Press the Automatic System Flush Button until soap comes out.
b. Press the Automatic System Flush Button again to turn it off.
2. Soap dispenser does not dispense soap and you cannot hear motor running. The green LED does not light up when
hands are under spout.
a. Be sure power is supplied to unit.
b. Make sure Fiber Optic Nut is tight on Fiber Optic Port.
Warranty:
SureFlo Automatic Liquid Soap Dispenser is warranted to be free from defects in workmanship and material under normal
usage from the date of purchase for a period of 3 years.
In the United States: BOBRICK WASHROOM EQUIPMENT, INC.
New York: 200 Commerce Drive, Clifton Park, NY 12065-1350 • Tel: (518) 877-7444 • Fax: (518)-877-5029
Los Angeles: 6901 Tujunga Ave, North Hollywood, CA 91605-6213 • Tel: (818) 982-9600 • Fax: (818)-503-9287
In Canada: BOBRICK WASHROOM EQUIPMENT COMPANY
© 2019 by Bobrick Washroom Equipment, Inc.
45 Rolark Drive, Scarborough, Ontario M1R 3B1 • Eastern Canada: Tel: (877) 423-6555 • Fax: (877) 423-8555
Form No. 858-191
r8/09/19
Printed in U.S.A.
• Western Canada: Tel: (877) 423-6444 • Fax: (877) 423-8444 or email [email protected]
3. Adjusting amount of soap
dispensed – Depending on
viscosity of liquid soap used,
unit may dispense between
0.4 ml to 3 ml of soap. To
reduce output of liquid soap,
rotate Portion Control Knob
counter-clockwise. To
increase the output of liquid
soap, turn the knob clockwise.
4. LED Light Indicators –
When in standby mode,
LED will flash green.
LED will turn off during
dispense. If red light is
flashing, remove hand to
allow unit to reset. Hand
must be removed for a
second activation.
4
Designer Series Automatic, Counter-Mounted Soap Dispenser
INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE
BOBRICK MODELS B-850, B-852, B-855, B-856, B-858 LIQUID SOAP DISPENSER
Clearances and Mounting Requirements:
• 1-3/8" (35mm) diameter mounting hole required.
• Minimum 18" (457mm) vertical clearance needed below the counter.
• 5" (127mm) diameter clearance needed below the mounting hole to
accommodate bottle and bottom housing.
• Minimum 2-1/4" (57mm) diameter clearance needed for Mounting nut directly
below the counter to clear sink rim.
• Recommend drilling mounting hole 6" to 8" (152 to 203mm) from the wall,
and 2-1/2" to 3" (64 to 76mm) from sink rim.
For New Installation:
• Refer to mounting template for drilling locations (Form No. 824-307).
For Retrofit:
1.
Remove existing dispenser(s).
2.
Clean area.
3.
Ensure hole is 1-3/8" (35mm) diameter.
4.
If necessary, enlarge opening using appropriate hole saw. For granite/marble counters, recommend using a diamond
hole saw (consult with stone and granite specialist). If needed, mounting hole should be offset to clear the sink rim. The Mounting
Nut requires 2-1/4" (57mm) diameter clearance directly below the counter.
Unit Diagram:
Item
Description
1
Top Assembly with Spout, Door and Stem
2
LED Light Pipe
3
Liquid Nozzle Tip
4
Fiber Optic Insert with Sensor Lenses
5
Rubber Counter Gasket
6
Wave Washer
7
Mounting Nut
8
Stem Mounting Nut
9
Duckbill Housing
10
Bottom Housing Assembly (includes Soap Bottle)
11
(3) Fiber Optic Cables for Sensor and LED Light Pipe
12
Fiber Optic Connector Tip Assembly
13
Fiber Optic Nut
14
Portion Control Knob
15
Automatic System Flush Button
16
Key Hole
17
BobKey
18
Fiber Optic Cable Cover
19
A/C Adapter Kit with U.S. Plug, Order Part No. 3974-57.
Optional: International AC Adapter Plug Kit
(UK, Europe Australia) 3974-55
Scan For SureFlo Installation and
Maintenance Instructions.
2
3
16
4
5
1
18
6
7
11
9
8
10
19
17
13
15
14
12
1