American Standard Triumph 7038 Manuale di istruzioni per l'installazione
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Prodotto idraulico American Standard Triumph 7038. American Standard Triumph 7038 7. Widespread lavatory faucet with speed connect drain

TRIUMPH
W idespread Lavatory Faucet with
Speed Connect™ Drain
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Screwdriver
1
INSTALL SPOUT
Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure
the SPOUT ESCUTCHEON (2) and SEAL WASHER (3) are properly seated.
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT
SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting
hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
1A
INSTALL VALVE BODY
Place RUBBER RING (9) into SCUTCHEON (10).
Install LOCKNUT (11) onto VALVE BODY (8).
From under side of mounting surface, install VALVE BODY (8) through valve
mounting holes. Threads of VALVE BODY (8) should extent at least 5/16
of a inch above mounting surface top. Fig. B. Thread ESCUTCHEON (10)
onto VALVE BODY (8) until snug against internal stop. If necessary, adjust
LOCKNUT (11).
Hand tighten LOCKNUT (11) to secure VALVE BODY (8).
Repeat above steps for opposite VALVE BODY (8A).
10
9
5/16'' MIN.
Fig. B.
Channel Locks
Turn off hot and cold water
CAUTION
supplies before beginning.
MOUNTING
SURFACE
11
8
Installation
Instructions
7038
Adjustable Wrench
1
10
9
8
11
1
Certified to comply with ANSI A112.18.1
Tubing Cutter
Fig. A.
1
2
3
SLOT
8A
M 9 6 8 8 6 8 R e v 1 . 2
7
4
5
6
12