14POINT7 UAFC Manuale d'uso - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso per Automobile Accessories 14POINT7 UAFC. 14POINT7 UAFC 13.

14POINT7 UAFC Manuale d'uso
ctrl+s = start/stop datalogging
4.6 Real Time Display and Datalogging
MAP/MAF In [v]: MAP/MAF voltage from MAP/MAF sensor.
RPM: RPM.
Scale [%]: Amount of MAP/MAF voltage scaling from Fuel Correction Table.
Bank: Which memory bank is currently selected; 0,1,2.
MAP/MAF Out [V]: Scaled MAP/MAF voltage to ECU.
Col Index LB: The lower Bound column Index of the Fuel Correction Table Cell.
Col Index UB: The upper Bound column Index of the Fuel Correction Table Cell.
Row Index LB: The lower Bound row Index of the Fuel Correction Table Cell.
Row Index UB: The upper Bound row Index of the Fuel Correction Table Cell.
Input 1 [v]: Analog input 1.
Input2 [v]: Analog input 2.
"TO", bottom middle, shows the number of communication timeouts.
"Rows Cap", bottom right, shows the number of data rows captured to memory which can be saved to disk.
Capture Data:
This will capture the data displayed on screen to memory, only data that has been "captured" can be saved to disk.
Save Data:
12
UAFC User Manual, Release Date: Aug 2 2016