All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
!
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Permit access for servicing blower as noted.
3. All building materials and wiring should be routed away from the air blower.
AIR MASSAGE SYSTEM:
The air bath should be installed on a 10 vac, 15 or 0 amp dedicated circuit. The circuit should be hard-wired
from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel.
A grounded neutral wire and a third wire, earth ground, are essential.
USE 15 OR 20 AMP
GFCI OUTLET
120 V AC
GND.
WI RE S E L E C TI O N GU I D E
M o t o r
H i P e r f o r man ce
R at i n g
2. 1 H . P .,
1. 4 H . P .,
a n d 1.2 5 H. P .
754063-100 Rev. B
AIR MASSAGE SYSTEM

ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
Ma x i m u m d i s ta nc e fro m
fu se b o x to m o to r
50 '
1 0 0'
1 15 V P o w e r L i n e
12
1 0
AIR BLOWER
1 5 0 '
2 00 '
8
8
CHROMATHERAPY LIGHT
CONTROL BOX (OPTIONAL)
T h e s i ze s s h o w n o n thi s
ch a rt are re c o m me n dati ons
fo r c o p p e r c o n du ctors
o n l y . Al w a y s f o l low
l o ca l a n d n a ti o nal
e l e c tri c a l c o d es