eKey TOCAnet Manuale di installazione - Pagina 10

Sfoglia online o scarica il pdf Manuale di installazione per Telecamera di sicurezza eKey TOCAnet. eKey TOCAnet 12. Networked access system with fingerscan

Technical data

6. Technical data
Connections
Connection to RS-485 bus
o
3 x relay 250V~ 5A (for doors / alarm systems / ...)
o
9VAC with supplied external adaptor
o
Memory
99 fingers possible
o
No loss of data after power failure
o
Security
Coupling between inside and outside unit(s)
o
Encrypted RS-485 bus communication
o
Extremely low rate of false identification
o
Dimensions W x H x D
outside unit: 60x95x55 mm
o
inside unit: 140x128x48 mm
o
Installation height of outside unit
approx. 135 cm upper edge
o
Operating voltage of internal unit
9 VAC or 12 VDC with controlled external adaptor,
o
outside unit is supplied via inside unit
Temperature range
-20° C to +70° C
o
Humidity
max. 95 %, IP43 outside,
o
IP54 inside (with high-strength cable gland)
Biometric characteristics
FAR: approx. 1,0 x 10 -5 at FRR 1,4 x 10 -2
o
Lifyecycle
approx. 1 million uses
o

Further information

Please find further information on our homepage www.ekey.net. There
you can find up-to-date hints and FAQ's.
- 10 -