eKey home KNX RS-485 Manuale di istruzioni per l'uso - Pagina 9

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Convertitore multimediale eKey home KNX RS-485. eKey home KNX RS-485 20.

Configuring in
a KNX system
8│en

Use

The ekey home converter KNX RS-485 can trigger 12 events in a KNX
system.
Event "ekey Event 1" - "ekey Event 10"
Events are triggered when an authorized finger is recognized on the ekey
finger scanner. Up to 10 events can be triggered. These events are
referred to as "ekey Event 1" to "ekey Event 10". Every identified finger
can trigger an event.
You can set the following functions for "ekey Event 1" to "ekey Event 10":
Function
Settings
switch
on/off
send value
0–100%
call scene
[scene number]
Table 2:
Description of ekey event 1-10
All 3 functions can also be activated simultaneously.
Event "Unknown"
The ekey event "Unknown" is triggered when the ekey finger scanner
does not recognize a finger.
No settings need to be adjusted for this function in the ekey system (ekey
control panel).
You can set the following functions for the ekey event "Unknown":
Function
Settings
switch
on/off
send value
0–100%
call scene
[scene number]
Table 4:
Description of event "Unknown"
Description
Switches an actuator on or off.
A control value between 0 and
100% is defined.
A scenario programmed in the KNX
system with the [scenario number]
is triggered.
NOTICE
Description
Switches an actuator on or off.
A control value between 0 and
100% is defined.
A scenario programmed in the
KNX system with the [scenario
number] is triggered.