American Standard SELECTRONIC 2506.1X3 Manuale di istruzioni per l'installazione - Pagina 6
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Cucina e accessori; sanitari per il bagno American Standard SELECTRONIC 2506.1X3. American Standard SELECTRONIC 2506.1X3 10. Moments proximity faucets
AC VERSIONS (HARDWIRE / PLUG-IN);
B
Fig. 2
CAUTION
Disconnect AC power supply before opening ENCLOSURE.
NOTE: For AC installation, make power supply connection
before mounting ENCLOSURE (3) to wall.
1. Remove ENCLOSURE COVER (1). Feed the
EXTENSION CABLES (2) from the Faucet through the
top of ENCLOSURE (3). Fig. 2.
FOR PLUG-IN HOOKUP ONLY
2a. Insert POWER CORD (8) through POWER SUPPLY
GROMMET (9) Fig. 2a.
3a. Insert POWER CORD (8) through side GROMMET (6) as
shown. Fig. 2a.
4a. Connect 27" EXTENSION CABLES (2) to SOLENOID
CABLE (7) and POWER CORD (8). Fig. 2a.
5a. Mount ENCLOSURE to wall. Replace ENCLOSURE
COVER (1). Tighten cover screws firmly.
6a. Plug AC POWER SUPPLY into wall outlet.
FOR HARDWIRE HOOK-UP ONLY;
2b. Insert one end of the 10' EXTENSION (10a) through POWER
SUPPLY GROMMET (9). Fig. 2b.
3b. Insert 10' EXTENSION (10a) through side GROMMET (6) as
shown. Fig. 2b.
4b. Connect 10' EXTENSION (10a) to single terminal of
Y-ADAPTER (11). Fig. 2b.
5b. Connect 27" EXTENSION CABLES (2) to SOLENOID CABLE (7)
and to either of the two terminals at the one end of the
Y-ADAPTER (11).
6b. Mount ENCLOSURE (3) to wall. Replace ENCLOSURE
COVER (1). Tighten cover screws firmly.
Contractor to supply ELECTRICAL BOX (12) and power to
POWER SUPPLY (13).
7b. Mount POWER SUPPLY (13) into ELECTRICAL BOX (12).
Connect White and Black connections to POWER SUPPLY
CONNECTIONS (14). Fig. 2c.
8b. Connect the10' EXTENSION (10b) to the POWER SUPPLY
CABLE (15). Fig. 2c.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
Fig. 2
2
3
Fig. 2a
7
2
8
Fig. 2b
2
2
11
10a
Fig. 2c
12
BLACK & WHITE
POWER
CONNECTIONS
5
1
PLUG INTO
WALL OUTLET
6
9
6
7
9
FROM ELECTRICAL BOX
WITH POWER SUPPLY
4" ELECTRICAL BOX
OR EQUIVALENT BY
OTHERS
14
13
CONNECTOR NOT
USED IN THIS
INSTALLATION
M965653 (11/14)
10b
15