P/N 1808922 Rev. C
STEP 1: Fully retract existing tarp into housing.
housing
STEP 3: Lift housing assembly and existing housing 10" to 12" from fully rested position.
existing
housing

Remove Spring-Loaded Housing from Base Assembly

12"
base
assembly
STEP 2: Insert 3/4" drive breaker bar or
ratchet into square drive on driver side of housing.
Slightly load tension onto roller bar. Carefully release pawl
on ratchet plate on inside of housing. Firmly hold breaker
bar and rotate pre-loaded shaft slowly counter-clockwise
to remove all tension from tarp roller.
3/4"
drive breaker bar
STEP 3: Support housing with hoist and lifting straps and
remove fasteners from bottom of housing. Do not
remove bolt holding cylinder to housing.
NOTE: Be careful straps are only supporting housing, not
base assembly mounting plate under housing.
STEP 4: Carefully lower housing assembly so housing is back
to fully rested position. With lifting straps still attached,
remove bolt holding cylinder rod to housing.
STEP 5: Lift housing off base assembly and carefully lower
housing to ground.
STEP 6: If existing tarp will be used with new tarp housing,
remove tarp from spring roller bar before discarding
old housing.
pawn
tarp roller