Sfoglia online o scarica il pdf Manuale d'uso e manuale d'installazione per Prodotto idraulico Astor-Bannerman ABW6SP. Astor-Bannerman ABW6SP 12. Height adjustable basin
•
Leave the clamp in place, fit the vertical rod
•
Fit the water supply solenoids.
•
Ensure the direction of flow, indicated by an arrow on the solenoid body, is correct this should
point towards the deck of the basin.
•
Connect the wiring to the actuator and water solenoids. Labels indicating the wire
positions are on the side of the electrical control box.
•
Touch taps:
Fit the sensors before mounting the unit on the wall
•
Touch tap sensors should be fitted in the position agreed with the client.
•
Drill an 18mm in the position required, take care to avoid items under the basin.
•
Position the coloured ring on the sensor and fit the securing nut.
•
Position the second sensor.
•
Wire the sensors into the control box behind the mirror
•
The basin assembly is now ready to be fitted to the high low frame
Remove the protective film from double-sided sticky tape fitted to the pivoting arms and place the
basin onto the support arms as far back as possible, ensuring the basin is under the white plastic
upper cover which holds the mirror.
HOT
COLD
SUPPLY
SUPPLY
The mains water supply can now be fitted.
•
Ensure both the hot and cold mains water supplies have been flushed and only then fit the open
ends of the supply hoses with the filter screens supplied onto the isolation valves.
•
Ensure the free end of the supply hoses are passed through the recess in the bottom left hand
side of the carcass of the rise and fall unit.
•
Connect the end of the supply hoses with the Conex fitting to the tap connectors.
Test the water supply:
•
Ensure the isolation valves are CLOSED. Place a bucket or suitable container below the plug
hole of the basin. Open both basin taps fully and then slowly open each of the isolation valves,
wait minutes, then examine the supply system for leaks, correct as necessary. Close the
isolation valves.
Fit the white plastic lower cover:
•
Remove the mushroom heads from the plastic rivets and place aside, fit the bodies into the six
holes in the frame
•
Remove the P Trap and straight coupling from the waste assembly.
•
Feed the free end of the flexible hose through the cut out in the lower right hand side of the
Hoses