Astra H-25 ES Manuale di installazione e sfruttamento - Pagina 8
Sfoglia online o scarica il pdf Manuale di installazione e sfruttamento per Caldaia Astra H-25 ES. Astra H-25 ES 20. Heating boilers
Damage
1. The set temperature
(power) cannot be
reached
2. Smoke breaks through
the doors
3. Ventilator isn't
operating
7. POSSIBLE DAMAGES
Cause
Not enough water in the heating
-
system;
Thermo regulator or ventilator is
-
broken;
Bad quality fuel (high moisture
-
content, very large firewood);
-
Heating surfaces of the boiler are
very impure;
-
No traction in the chimney (impure) –
the upper ignition is congested;
-
Ceramic burner is foul.
-
Tightening rope is damaged;
-
Doors are leaky along the whole
perimeter.
-
No traction in the chimney
-
Emergency thermostat went off
(switch light of ventilator is off);
-
Thermo regulator or ventilator is
broken;
Disconnection of electricity supply.
-
Ways of elimination
Fill up
Replace
Use dry fuel, split firewood
Clean
Clean
Clean
Replace with a new one
Adjust hinge supports and door
lock (regulated screwing or
unscrewing door hinge or lock
screws) (see. Fig.2)
Clean.
Call representatives of the service
company; turn on after indication of
the causes (see section 5)
Replace
Check electric fuses of the building,
call the electrician
8 |