DoorHan SHAFT-120 Manuale d'installazione e d'uso - Pagina 10
Sfoglia online o scarica il pdf Manuale d'installazione e d'uso per Apriporta DoorHan SHAFT-120. DoorHan SHAFT-120 12.
Anche per DoorHan SHAFT-120: Manuale d'installazione e d'uso (12 pagine)
7. OPERATOR PROGRAMMING
The operator has four variants of operation logic. You can choose any lolgic by positioning the DIP-switches on the control
block as described in the table below.
LOGIC #1
LOGIC #2
LOGIC #3
LOGIC #4
8. RELEASE OPERATION
The electric operator Shaft-120 is equipped with a manual chain reducer, which is used for emergency lifting/lowering of the
door in case of a power cut. For emergency control, pull the cord with a red handle down up to the stop to prevent automatic
actuation of the operator. To return to the automatic control, pull the cord with a green handle down up to the stop.
WARNING! It is forbidden to pull down the cord with a red handle, when the operator runs, as this can damage the motor.
WARNING! Intensive regular use of the manual chain reducer is not permitted. Use it in case of emergency only.
WARNING! Using the manual chain reducer, make sure, that the chain links are not deformed or dirty. Otherwise the
reducer can be jammed.
If required, the door can be opened using the chain. Lengthen or shorten the chain so that its assembled edge hangs 50–
150 cm above the floor. It is recommended to fix the lower part of the chain which can be a hindrance to people and equipment.
Place the warning labels, showing closing and opening direction, in plain view.
WARNING! Use the chain only in case of emergency;
otherwise the reducer parts can be damaged.
10
Off
On
Automatic closing function is off
The door will close after the control button has been pressed and released
The door will open after the control button has been pressed and released
Off
On
Automatic closing function is off
The door will close while the control button is pressed and hold down
The door will open after the control button has been pressed and released
Off
On
Automatic closing function is off
The door will close while the control button is pressed and hold down
The door will open while the control button is pressed and hold down
Off
On
Automatic closing function is on (delay is 30 s)
The door will close after the control button has been pressed and released
The door will open after the control button has been pressed and released
OPERATOR PROGRAMMING