DoorHan DCUH-3 Manuale d'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale d'uso per Unità di controllo DoorHan DCUH-3. DoorHan DCUH-3 16. Control unit for electrohydraulic dock leveler with hinged lip
Anche per DoorHan DCUH-3: Manuale (12 pagine)
Table 6.1.2. LCD display indication in DCUH-2 mode
Dock equipment
Dock leveler
In DCUH-3 mode each operation of the door and dock leveler is displayed on the menu screen accordingly (see Ta-
ble 6.1.3).
Table 6.1.3. LCD display indication in DCUH-3 mode
Dock equipment
Door
Dock leveler
If it is time to perform maintenance, the operation indica-
tion is blocked, the SEr message is constantly displayed
on the menu screen and the service led is lit. In order to
remove a service tick enter the advanced programming
menu. The same applies to the faults indication: if a fail-
6.2. TO ENTER PROGRAMMING MENU
In order to enter the programming menu turn the main
power switch ON. Make sure the power indicator is lit, then
press and release the RAISE button. After that press the P
and RAISE buttons simultaneously and hold for 5 seconds.
Table 6.2.1. Parameters of the DCUH-2 programming menu
Message
Parameter value 1–9 — 3–11 sec.
1. UH
Default value — 7 sec.
Change of value by 1 equals 1 sec.
Parameter value 1–9 — 5–21 sec.
2. UC
Default value — 13 sec.
Change of value by 1 equals 2 sec.
Parameter value 1–9 — 2,5–6,5 sec.
3. Hd
Default value — 4,5 sec.
Change of value by 1 equals 0,5 sec.
Parameter value 1–9
4. AF
(Y/n), default value — Y
5. Ar
6. CXX
7. SXX
8. EXX
(Y/n), default value — n
9. rS(1)
Menu screen message
Menu screen message
Setting option
(0–99)
(0–99)
(0–99)
PUP
Pdn
GUP
Gdn
GSt
PUP
Pdn
ure occurs during operation, EX message will be displayed
before the system is de-energized, where X is the fault
number. The number of the last fault may be viewed in the
advanced programming menu.
Flashing UH message on the menu screen confirms you
have successfully entered the programming menu.
Description
Time period in which hydro station motor stops during leveler
Leveler lowering time in auto parking mode
Leveler raising time at the last stage of parking
Operating threshold of the leveler stop function during leveler rais-
ing mode only
Activation of auto parking function
Cycles counter / 1000
Service counter
Indication of the last equipment failure:
E00 — no equipment failures during the whole period of operation;
E01 — usage error;
E03 — short circuit in hydraulic station motor winding;
E04 — control board short circuit
Reset of service mode
Operation
Leveler rising
Leveler lowering
Operation
Door rising
Door lowering
Door stopping
Leveler rising
Leveler lowering
raising
9