DoorHan SMARTROLL Manuale di istruzioni per la programmazione - Pagina 8

Sfoglia online o scarica il pdf Manuale di istruzioni per la programmazione per Controllore DoorHan SMARTROLL. DoorHan SMARTROLL 12. Control board

DoorHan SMARTROLL Manuale di istruzioni per la programmazione
Connec-
Type
Colour
tor
8
Terminals
Device connection
Title
STEP-BY-STEP CONTROL command. Closing the contacts of the device connected
1
SBS
to this terminal generates step-by-step control: open — stop — close — stop
OPEN command. Closing the contacts of the device connected to this terminal
2
Open
makes the control unit to open
CLOSE command. Closing the contacts of the device connected to this terminal
3
Close
makes the control unit to close
4
GND
Common contact
STOP terminal. Opening the contacts of the device connected to this terminal makes
1
Stop
the control unit to stop roller shutter movement
Connection of photocells (NC). These devices are designed to prevent pinching of
people, animals and foreign objects in the rolling shutter opening. Response of the
2
Ph.CL
devices results in immediate reverse movement of the shutter. If the shutter is open
and the sensors connected to these terminals are activated, this will prevent any
movement of the rolling shutter
3
GND
Common contact
1
(+)
Unstable voltage, +24 V
2
(–)
1
Connection of the built-in LED lamp
2
1
Ext.Lamp
External signal lamp connection, 220–240 V
2
1
M-N
Common terminal of an electric motor (blue wire from the motor)
2
M-L1
Closing terminal of an electric motor (black wire from the motor)
3
M-L2
Opening terminal of an electric motor (brown wire from the motor)
1
N
2
L
Mains connection 220–240 V and grounding
3
PE
ELECTRICAL CONNECTIONS
Table 1.1 continued