DoorKing 1601-295 Manuale d'uso - Pagina 4

Sfoglia online o scarica il pdf Manuale d'uso per Apriporta DoorKing 1601-295. DoorKing 1601-295 8. Break-away octagon arm installation kit
Anche per DoorKing 1601-295: Manuale di installazione (11 pagine)

Plug in Break-Away Switch (REQUIRED) and Reverse Edge (Optional)
Option #1
Reverse Edge Plug (Optional)
Secure ALL Wires to
Bracket and Install Cover
Note for Older Covers:
See page 6.
Zip Tie
1601-269-D-2-20
Break-Away Switch Plugs
(Required)
Option #1
IMPORTANT:
Allow for some slack in the reverse
edge wire to account for the arm pivoting when arm
"Breaks Away" from bracket. Test break-away
feature to make sure there is enough slack wire.
Note: The reverse edge plug is not used
when not installing a reverse edge.
Break-Away Switch (REQUIRED)
IMPORTANT: Break-Away switch is located between the
release rollers and MUST be connected to wire harness.
DO NOT OPERATE ARM WITHOUT
BREAK-AWAY SWITCH FUNCTIONING.
IMPORTANT:
Make sure that all wires remain clear of
the pivoting arm and the plastic cover.
Zip Tie
4
Option #2
Break-Away Switch Plugs (Required)
Reverse Edge Plug (Optional)
Use included zip ties to secure ALL
wires to break-away arm bracket.
Option #2
Allow for some slack in the
reverse edge wire to account for
the arm pivoting when arm
"Breaks Away" from bracket. Test
break-away feature to make sure