Astralpool A144C3 Manuale d'uso - Pagina 7
Sfoglia online o scarica il pdf Manuale d'uso per Pompa dell'acqua Astralpool A144C3. Astralpool A144C3 16. Self-priming commercial centrifugal pumps with trap for swimming pool use
IAPMO Certified
Anti-entrapment
Cover or Suction Fitting,
screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Figure 1 – Recommended pump suction layout.
Use larger pipe as required to keep water velocity below 7 feet per second or
local construction code limits, whichever is lower.
Suction pipe must rise continuously from source to pump. To avoid airlock-
ing, do not allow high spots in pipe.
When using reducer to connect to pump flange, use an eccentric reducer with
the straight side on top.
Piping – Discharge
Maximum water velocity should be 7 feet per second in metal pipe or 10 feet
per second in plastic pipe.
To minimize friction losses, make piping one size larger than pump openings.
Fittings restrict flow; for best performance use fewest possible fittings.
Avoid fittings which could cause an air trap.
Pool fittings must conform to International Association of Plumbing and
Mechanical Officials (IAPMO) standards.
POOL PUMP SUCTION
REQUIREMENTS
Pump suction is hazardous and can trap and drown or disem-
bowel bathers. Do not use or allow anyone else to use a pool, spa, or hot tub
unless it has at least two suction outlets to each pump suction line (see
"Outlets Per Pump," Page 8). Do not use or operate swimming pools, spas,
or hot tubs if a suction outlet cover is missing, broken, or loose. Follow the
guidelines below for a pump installation which minimizes risk to users of
pools, spas, and hot tubs.
Entrapment Protection
The pump suction system must provide protection against the hazard of
suction entrapment or hair entrapment/entanglement.
At Least
3 Feet
No valves between
Tee and Main Drains
Valves OK between
pump and Tee
Cover or Suction Fitting,
7
IAPMO Certified
Anti-entrapment
screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Pump
2762 0197