About the DataMan Control Box
The DataMan Control Box provides additional functionalities when connected to
a DataMan 50 or 60.
The DataMan Control Box has two buttons and a buzzer. The buttons are
connected to Input lines 0 and 1 on the DataMan 50 and 60. The buzzer is
connected on the Output 0 line.
2 Control Box Reference Guide
Input Line Options
Input Line 0 is hardwired to Trigger On. You can decide what you
connect Input Line 1 (the TUNE button) to, by checking a functionality
on the System Settings pane's Inputs tab's Input line 1.
To use the buttons on the Control Box,
change the default Manual trigger
mode on the Light and Imager Settings
pane to any trigger mode other than
Manual and Presentation. Press the
TUNE button and then the TRIG button
in order for the funtionality connected
to the TUNE button to work.
For demonstration purposes, the recommended settings for DataMan 50
or 60 Input 1 options are Train Code and Optimize Brightness checked
(others unchecked), Pulse Width 50 ms.
The default buzzer duration is 5 ms.
On the System Settings pane's Outputs
tab, you can set it to maximum 10000
ms.
Control Box Reference Guide
3