Table 1-5
System Error Messages (continued)
Message
Keyboard Interface
Error
Memory Error at:
MMMM:SSSS:OOO
(W:XXXX, R:YYYY)
where:
M: MB, S: Segment,
O: Offset,
X/Y: write/read pattern
CPU Clock Mismatch
Onboard Serial Port 1
Conflict
Onboard Serial Port 2
Conflict
Onboard Parallel Port
Conflict
Pointing Device Error
Pointing Device
Interface Error
Press F1 key to
continue or Ctrl-Alt-Esc
for Setup
Real Time Clock Error
System Board
Action
Replace the keyboard or contact
your dealer.
Check SIMMs on the system board.
Contact your dealer.
Run Setup. Check if the CPU clock is
correct. If correct, exit Setup and
reboot the system. If the error
message reappears, ask for technical
assistance.
Run Setup and disable the port.
Run Setup and disable the port.
Run Setup and disable the port.
Check and connect pointing device.
Replace the pointing device or
contact your dealer.
Press
or
+
+
Setup.
Check the RTC chip. If it is still good,
run Setup. If not, replace the RTC
chip.
to enter