Specifications
DC Voltage
DC Voltage Accuracy
DC Current
DC Current Accuracy
AC Voltage
AC Voltage Accuracy
AC Current
AC Current Accuracy
Inrush Current
Inrush Current Accuracy
Resistance
Resistance Accuracy
Continuity
Diode
Capacitance
Capacitance Accuracy
Frequency
Frequency Accuracy
Duty Cycle
Duty Cycle Accuracy
Sampling Rate
Operating Temperature
Display
Battery
Item 64017
Ranges: 60mV / 600mV / 6V / 60V / 600V / 1000V
(@60mV-600V) ± 0�5% of rdg + 5D
(@1000V) ± 0�8% of rdg + 4D
Ranges: 60A / 600A / 1000A
± 2�0% of rdg + 8D
Ranges: 60mV / 600mV / 6V / 60V / 600V / 750V
Frequency Range: 40-400Hz
(@60mV-600V) ± 0�6% of rdg + 5D;
(@750V) ± 0�8% of rdg + 4D
Ranges: 60A / 600A / 1000A
Frequency Range:
(@0A - 600A) 40-400Hz
(@600A-1000A) 40-60Hz
± 2�0% of rdg + 8D
Ranges: 60A / 600A / 1000A
Frequency Range: 40-400Hz
(@0A-60A) Reference only;
(@600A-1000A) ± 5�0% of rdg + 60D
Ranges: 600Ω / 6kΩ / 60kΩ / 600kΩ / 6MΩ / 60MΩ
(@600Ω-600kΩ) ± 0.8% of rdg + 3D
(@6MΩ-60MΩ) ± 2.0% of rdg + 5D
Meter beeps at < 50Ω
Forward DC Current: ~ 1mA
Reverse DC Voltage: ~ 3�2V
Ranges: 9�999nF / 99�99nF / 999�9nF /
9.999μF / 99.99μF / 999.9μF / 9.999mF / 99.99mF
± 3�0% of rdg + 5D
Current Mode Range: 100Hz / 1000Hz
Voltage Mode Range: 100Hz / 1000Hz / 10kHz
Hz/Duty Mode Range: 10Hz / 100Hz / 1000Hz /
Current Mode: ± 1�5% of rdg + 5D
Voltage Mode: ± 1�5% of rdg + 5D
Hz/Duty Mode: ± 0�3% of rdg + 5D
0�1%-99�9%
± 3�0%
~3 samples per second
Range: 64�4°F - 82�4°F (18°C - 28°C)
Liquid Crystal Display (LCD)
9V (Included)
For technical questions, please call 1-888-866-5797.
10kHz / 100kHz / 1000kHz / 10MHz
Page 5