Akw AKW23116 Istruzioni per l'installazione, la manutenzione e l'uso - Pagina 6

Sfoglia online o scarica il pdf Istruzioni per l'installazione, la manutenzione e l'uso per Prodotto idraulico Akw AKW23116. Akw AKW23116 16. Basin mixer valve

Installation
1. Remove the check valve and filter assemblies from the union nut.
Note: Take care not to loose the sealing washers.
2. Screw the fixing bolts fully into the T301 body.
3. Place the Rubber Washer (44mm od) in the groove in the base of the T301 body.
3. Screw the red flexible inlet tail into the T301 hole marked with a 'RED DOT'
(nearest to the spout) and tighten. Screw the blue hose into the remaining hole
marked with a 'BLUE DOT' and tighten. Position the T301 onto the basin.
4. Make sure that the T301 is correctly positioned, fit the rubber washer (47mm od)
on the underside of the basin, place the horse shoe washer on top of the
rubber washer and screw the fixing nuts onto the fixing bolts. Tighten the fixing
nuts until the tap is secure. DO NOT OVERTIGHTEN THE FIXING NUTS.
5. Connect the check valve and filter assemblies onto the isolating valves
(not supplied) which are connected to the supply pipework.
Use a suitable 22mm A/F spanner to tighten the check valve assemblies.
6. Locate the sealing washer inside the union nut on the flexible inlet tail and screw
onto the check valve and filter assemblies.
The red inlet tail must be connected to the hot supply (Refer to 3 above).
Use a suitable spanner 24mm A/F spanner to tighten the
union nuts.
7. Restore the water supplies and check
all connections are watertight.
Refer to the 'Commissioning' section.
6