Akw M11 DigiPump Istruzioni per l'installazione e la cura dell'utente - Pagina 13
Sfoglia online o scarica il pdf Istruzioni per l'installazione e la cura dell'utente per Prodotto idraulico Akw M11 DigiPump. Akw M11 DigiPump 20.
Flow Sensor Connection
Flow sensor
cables
Pump spacer connection
Seperate the spacers, remove the adhesive backing and snap into position.
CONNECTING FLOW SENSOR TO M17 DIGIPUMP
Any unused sensor wires must be terminated in a connector block and insulated using electrical insulation
tape at a dry location. Failure to do this may damage the pump.
Ensure the pump spacers are used to prevent the cables from being trapped.
CONNECTING FLOW SENSOR TO COMPATIBLE SHOWER
To connect the flow sensor cable directly to a compatible electric shower please see the
instructions supplied with your electric shower.
Power cable
Pump
Spacers
Flow Sensor
Connects to
Red
+
Brown
Connects to
S
Connects to
Black
-
All cable connections must be in a dry location.
Flow Sensor
Red
Wire
Brown
Black
Pump
Red
White
Black
Connector Block
Red
+
White
S
Black
13
Only remove the
adhesive tab at this
hole.
Pump Wire