Akw MediCare Istruzioni per l'installazione e la cura dell'utente - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione e la cura dell'utente per Prodotto idraulico Akw MediCare. Akw MediCare 2. 15mm or 22mm pw50 pumped waste

Installation Instructions
Before installation check the shower base area (8) slopes correctly towards the waste and the waste
outlet pipe is laid in the shortest distance to the pump.
Push the deburred end of a ø15mm or ø22mm Polypipe* or equivalent (not supplied) firmly into position
following all the normal JG Speedfit assembly precautions and instructions.
Fit the JG adaptor locking ring (3) (supplied).
Locate the waste in the required position, ensuring the main body seal (4) is firmly in position, and is
in contact with the underside of the shower base.
Align and fit the clamping ring (5), by turning the ring clockwise to tighten.
Fit the grid (6), by lowering into recess within the waste body.
Position the cover (7) over the assembly and rotate the cover until the lugs snap into place.
User Care Instructions
AKW pumped wastes are designed for low maintenance and reliable operation. The pumped waste
should be checked as part of a planned maintenance programme, retightening the screws as required
and any part showing evidence of damage or misuse must be replaced.
Keeping your Pumped Waste Clean
This product should be cleaned periodically to remove any accumulation of hair or other detritus, using
normal domestic bathroom cleaning materials.
To open and clean the trap, first remove the cover (7) by rotating anti-clockwise, until it clicks free.
Lift the cover off by gripping the edges. Lift the grid (6), up vertically by gripping the centre peg.
Reinstall by reversing the order of the above instructions.
Disinfecting
Where disinfecting is necessary, standard established procedures for disinfecting equipment should be
used with due care and attention taken of the warnings below concerning possible effects of aggressive
chemicals on plastics.
After cleaning always flush down with water then wipe thoroughly with a damp cloth to remove any
cleaning material residues before drying off.
Do not use strong or concentrated acidic, alkaline or other cleaning materials as these may discolour or
otherwise damage the product.
AKW do not approve or recommend autoclave cleaning of any of the components due to the damage
this can cause to the special engineering plastics used in the construction of this product.
8
5
4
2
3
Sectioned view of the PW 50
Packaging
This waste is supplied in a polypropylene (PP) bag to keep the product unsoiled until installation; it may
also be packed in a cardboard box. Both are suitable for recycling operations and should be disposed
of in accordance with local recycling regulations.
7
6
1