Dor-O-Matic 96000 Series Manuale di istruzioni per l'installazione - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Controllore Dor-O-Matic 96000 Series. Dor-O-Matic 96000 Series 7. Slide control

1.
Close doors.
2.
If the 4-position switch is used, be sure it is in the "2-way" position before proceeding.
3.
Apply power to the system using the main power switch on the header/cover.
4.
Apply an activation signal (activate inside or outside motion sensor, press keypad "test activate" or momentarily move the
4-way to the hold position).
5.
Observe sizing cycle. If door slams open or closed, reduce sizing speed (SS) setting. Remove power and repeat steps 3
to 5.
Note: Allow the door to remain at the fully closed position for a minimum of one (1) second to complete the sizing
mode.
Caution: If the door sizing speed is set too fast, blown fuses and/or a tripped circuit breaker may occur if the
doors are activated when manually locked.
6.
After sizing is complete, make adjustments to other settings as needed.
84657-084 REV. B
SETTING
: OPENING SPEED
: AUTO-REVERSE-OPEN
: BACKCHECK POSITION
: BACKCHECK SPEED
: HOLD-OPEN DELAY
: CLOSING SPEED
: AUTO-REVERSE-CLOSE
: LATCH POSITION
: LATCH SPEED
: ENERGY-WISE POSITION
: ELECTRIC LOCK
: SIZING SPEED
: FUNCTION
: STATUS ANNOUNCEMENT
KEYPAD LABEL DRAWING
July 2003
TEST
ACTIVATE
SETTING
VALUE
UP
UP
DEFAULT
DOWN
DOWN
84725-600 REV. 0