Akw Arka 25421-2 Manuale di istruzioni per l'installazione - Pagina 7

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Apparecchiature per il bagno Akw Arka 25421-2. Akw Arka 25421-2 16. Thermostatic tmv3 bar mixer shower

Step 1: Adjusting the temperature setting
for a tmV3 installation, the maximum blended temperature should be set to 41 °C.
for a non-tmV3 installation, the maximum blended temperature can be set to above 41 °C.
1. turn the temperature lever to the 38 °C mark and test that the temperature of the water from
the shower outlet is 38 °C. if the water is not 38 °C, proceed with the following procedure.
2. turn the temperature lever to the fully cold position.
3. Hold the temperature override button down and slowly turn the lever until the output water
reaches 38 °C.
4. Wait for the water temperature to stabilise. Turn the flow lever to the off position.
5. Without turning the temperature lever, unscrew the screw and remove the paddle lever.
6. Remove and rotate the Limit Ring until the 38 °C step is in line with the notch on the valve
and the 38 °C number mark on the shower mixer body.
Replace the lever with the temperature mark aligned with the 38°C position on the shower mixer.
7. Hold the temperature override button down and turn the lever to maximum temperature.
measure the stabilised water temperature. if the temperature is not 41 °C, set the lever with
the temperature mark aligned back in the 38 °C position and remove the lever.
Step 2: : Pull out the limit ring and override limit ring, get them apart.
Remove and rotate the override Limit Ring accordingly to the steps in the table below and
repeat this process until the maximum override temperature is set at 41 °C.
Order: 01905 823 299
Limit Ring
Step 3: : See the arrow below, the step side of override limit ring to get align with the differen
scales marked on limit ring. After that, push the override limit ring in place.
( ( Different scale reflects different temperature) )
override
Limit Ring
Limit Ring
|
orders.akw-ltd.co.uk
Commissioning
41 °C Step
temperature Lever
Step 3: : See the arrow below, the step side of override limit ring to get al
scales marked on limit ring. After that, push the override limit ring in plac
( ( Different scale reflects different temperature) )
38°C Step
41°C Step
Technical Support: 01905 560 219
override Limit Ring
temperature mark
override Button
7