Doran 4100 Manuale operativo e di servizio - Pagina 13
Sfoglia online o scarica il pdf Manuale operativo e di servizio per Bilance Doran 4100. Doran 4100 13. Digital checkweigh scale
DORAN MODEL 4100 OPERATING AND SERVICE MANUAL
Type 15: Keyboard Data Entry: Sealed neoprene keypad for entry of Tare, 8
Setpoints, and Over and Under tolerance values.
Type 16: Remote Tare/Print Switch: Remote switch for ZERO or Print request.
Type 18: Accumulator: Accumulate weight data. Recall subtotal and total weight.
Type 20: Mounting Feet: Mounting feet for 4100RSS to table mounting of
4100RSS.
Type 21: Grading Option: Provides capability for eight weight grade ranges.
Values are entered via sealed keypad.
Type 23: Stainless Steel Load Cell: Potted Stainless load cell for harsh
environments. For 4100, 410012S, and DSP4100 only.
Type 24: Stainless Pushbutton Cover: A stainless steel cover to replace neoprene
rubber boot for maximum durability.
Type 25: 230 VAC Operation: Special transformer and fuse for 230 VAC, 50/60 HZ
operation.
Type 26: Heat Resistant Platter: Insulates platter and load cell from excessive heat
(1200
Contact Doran for more information and pricing and availability of options.
MAN001R2
o
F) encountered in glass manufacturing.