FLYGT FLS Manuale di installazione e applicazione - Pagina 11

Sfoglia online o scarica il pdf Manuale di installazione e applicazione per Sensori di sicurezza FLYGT FLS. FLYGT FLS 12. Leakage detectors

FLS stator leakage sensor
Signal:
Supply voltage:
Max. temperature:
Test temperature:
Max. duty temperature:
Material:
Physical size, sensor
Length:
Width:
Height:
Part Number
CLS water in oil sensor
Trip emulsion:
Signal:
Poles:
Supply voltage:
Metal parts:
Sensor surface:
Max. pressure:
Test pressure:
Duty pressure:
Max. temperature:
Test temperature:
Max. duty temperature
Physical size, sensor
Length:
Diameter:
Thread:
Part number:
Warning: Sensor body made of glass.
Handle with care.
TECHNICAL DATA
8 mA non-alarm current,
36 mA alarm current
12 VDC
90°C, 1h
115°C, 1h
70°C
Aluminium
27 mm
16 mm
16 mm
518 89 02
35% of water in oil
5.5 mA non-alarm current,
29mA alarm current
(5 s delay of alarm)
2 wires protected with a
diode (wrong polarity
connection = 0 mA)
12 VDC (± 10 %)
(brown = +. black = –)
Acid proof stainless steel
Glass
10 MPa 1h
40 MPa
2 MPa
90°C, 1h
115°C, 1h
70°C
75 mm
12 mm
M16 × 1.5, length 15 mm
505 12 00
FLS10 inspection chamber sensor
Signal:
Supply voltage:
Max. duty temperature:
Material:
Physical size, sensor
Length:
Diameter:
Thread:
Part number
11
10 mA non-alarm current,
28 mA alarm current
12VDC
90°C
Stainless steel and
nitril rubber
44 mm
22 mm
M12 × 1, length 9 mm
608 26 00