AstroAI DT201D Manuale di istruzioni per l'operatore - Pagina 10
Sfoglia online o scarica il pdf Manuale di istruzioni per l'operatore per Strumenti di misura AstroAI DT201D. AstroAI DT201D 19. Auto range digital clamp meter

5. SPECIFICATIONS
Accuracy is guarantied for 1 year 23°C±5°C less than
80%RH
5-1. DC VOLTAGE (Auto ranging)
Input Impedance: 10MΩ
Range
600mV
6V
60V
600V
1000V
Overload Protection:
600V AC RMS CAT III, 1000V AC RMS CAT II
Max. Input voltage:
600V AC RMS CAT III, 1000V AC RMS CAT II
5-2. AC CURRENT (Auto ranging)
Measuring voltage drop: 200mV
Range
60A
600A
1000A
show True-RMS value
5-3. AC VOLTAGE (Auto ranging)
Range
600mV
6V
60V
600V
750V
Resolution
0.1mV
1mV
10mV
100mV
1V
Resolution
10mA
100mA
1A
Resolution
0.1mV
1mV
10mV
100mV
1V
±(0.8% of rdg + 5dgts)
±(0.8% of rdg + 3dgts)
±(1.0% of rdg + 5dgts)
Accuracy
±(2.5% of rdg + 10dgts)
±(1.2% of rdg + 8dgts)
±(1.2% of rdg + 6dgts)
±(1.2% of rdg + 8dgts)
- 9 -
Accuracy
Accuracy