5.
Environmental Factors and Requirements
Operating Temperature:
Humidity:
Atmospheric Pressure:
Noise (sound level):
Ozone Emissions:
NOTE
It may be necessary to use a humidifier or dehumidifier to attain the proper
humidity levels for optimal machine performance.
5.1 Temperature and Humidity Conditions
The machine should not be installed in locations with significant shifts in
temperature and humidity (outside the base specifications). Areas containing
water, or equipment that generates a heat discharge, such as a heater or
stove, should be avoided unless proper control is available.
During operation, the permissible humidity range is 30% to 70% RH (Relative
Humidity) with a room temperature of 68°F to 80.6°F (20°C to 27°C).
There is a risk that paper feeding and image quality may be affected if the
machine is used in a location that does not meet these specifications.
The permissible humidity range for storing paper is 30% to 70% RH (Relative
Humidity) with a room temperature of 68°F to 80.6°F (20°C to 27°C). Storing
paper in a location that does not meet these specifications may affect paper
feeding and image quality. For example, if the humidity is too high, paper
curling and paper jams will increase. If the humidity is too low, paper may
shrink, lose resistance, and toner will not adhere to the paper as well.
5.2 Temperature Gradient
Using an air conditioner during the winter, or if a sudden temperature change
occurs, may have an adverse affect on image positioning. Sudden
temperature changes may cause the paper to bend or contract, and cause a
machine malfunction due to condensation. To avoid these issues, control the
temperature gradient so that it does not exceed 18°F/H (10°C/H).
Version 1
Between 68°F (20°C) and 80.6°F (27°C)
Between 30% and 70%
810.6 to 1,013 hPa (0.8 to 1.0 atm)
Standby: 74 dB; Copying: 82 dB
0.01 ppm (parts per million) or less (initial startup)
0.035 ppm or less (after a short break-in period)