daewon DIB-N850R Manuale d'uso - Pagina 16

Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature per il bagno daewon DIB-N850R. daewon DIB-N850R 20.

Error code

※ In the event of an abnormality, please refer to the error code table below and inform
us at the time of receiving repair service, so that the action may be easier.
Remote model
Common display
Left
Seat temperature "Green" LED blinks
Seat temperature "RED" LED blinks
Water temperature "Green" LED blinks
Water temperature "Green" and Yellow" sequentially blink
Water temperature "RED" blinks
Energy saving
"Green" and "Red"
Water temperature "Yellow" and "Red" sequentially blink
LED sequentially
Blink, and
Night light "Red"
blinks
Side arm model
Side arm model
Left
Seat temperature "Green" LED blinks
Seat temperature "RED" LED blinks
Water temperature "Green" LED blinks
Water temperature "Green" and Yellow" simultaneously blink
Water temperature "RED" blinks
Energy saving
"Green" and "Red"
Water temperature "Yellow" and "Red" simultaneously blink
LED sequentially
Blink, and
Night light "Red"
blinks
Error code display priority
Error code display is divided into two sections, 1 to 6 and 7 to 14. Error with a smaller number is displayed only.
For example, if No. 1, No. 6, No. 8, and No. 14 occur simultaneously, only No. 1 and No. 8 are displayed. If 1 is
solved, only 6 and 8 will be displayed, if 8 is solved, 6 and 14 will be displayed.
30
No.
Right
1
Disconnected or not inserted seat temperature sensor
2
Short or overheated seat temperature sensor
3
Disconnected or not inserted intake water temperature sensor
4
Short or overheated intake water temperature sensor
5
Disconnected or not inserted outlet water temperature sensor
6
Short or overheated outlet water temperature sensor
7
Low voltage
Solenoid valve overcurrent
8
9
Solenoid valve disconnection
Drying fan motor disconnection or overcurrent
10
11
Deodorizing fan motor overcurrent
12
Pump motor overcurrent
13
Flow meter disconnection or abnormality
Overvoltage
14
Right
No.
1
Disconnected or not inserted seat temperature sensor
2
Short or overheated seat temperature sensor
3
Disconnected or not inserted intake water temperature sensor
4
Short or overheated intake water temperature sensor
5
Disconnected or not inserted outlet water temperature sensor
6
Short or overheated outlet water temperature sensor
7
Low voltage
Solenoid valve overcurrent
8
Solenoid valve disconnection
9
10
Drying fan motor disconnection or overcurrent
11
Deodorizing fan motor overcurrent
12
Pump motor overcurrent
13
Flow meter disconnection or abnormality
14
Overvoltage
Specification
DIB-N810/DIB-N830/
Item
DIB-N850
Power voltage
AC 220V / 60Hz
Max power consumption
1,430W
Power cord
1.8M
Supply water connection
Directly connects to the water pipe
Supply water pressure
0.068 ~ 0.735 MPa
Rear wash
650±50cc/min (850±50cc/min at 2X mode)
Front wash
Volume
650±50cc/min (800±50cc/min at 2X mode)
Turbo(enema)
760±50cc/min
Rear/Front wash (10 levels incl. 2X mode)
Wash
Pressure control
Turbo(enema) 5 levels
Temperature control
4 levels (Off, low, middle, high)
Max heater power
1,400W
consumption
Safety devices
Thermal sensor, Thermal fuse, Thermal switch
Temperature control
4 levels (Off, low, middle, high)
Max heater power
38W
Heated seat
consumption
Safety devices
Thermal sensor, Thermal fuse
Temperature control
5 levels
Heater capacity
400W
Dry
Safety device
Thermal fuse
Deodorizer
Catalyst Carbon deodorization filter (replaceable)
3 ~ 35℃ (12 ~ 35℃ recommended)
Incoming water temperature tolerance range
3 ~ 40℃ (10 ~ 35℃ recommended)
3 ~ 40℃ (10 ~ 35℃ recommended)
Usage room temperature tolerance range
3 ~ 40℃ (10 ~ 35℃ recommended)
Elongated
449mm X 528mm X 112mm 380mm X 528mm X 112mm
Product
dimensions
Round
449mm X 500mm X 112mm 380mm X 500mm X 112mm
Frequency band
2440 Mhz
Modulation type
OQPSK
Antenna type
Internal antenna
Wireless type
Zigbee
Product weight
4~4.5kg(6.5~7kg)
DIB-N810R/DIB-N830R/
DIB-N850R
31